The ONT configuration status fails

Hello everyone!

Today I would like to share with you a case about the fact that the ONT configuration status fails. See more information shown below.

Product model: MA5608T

 

Issue description

 

After an ONT(here we use EG8141A5) is added to the MA5608T, a user runs the display ont info command to query the ONT status. The command output shows that the config state is failed.

The ONT configuration status fails 1

Issue analysis

1. Run the display ont failed-configuration command to check the ONT configuration restoration failure information.

The ONT configuration status fails 2

2. Query the ONT line configuration.

The ONT configuration status fails 3

3. Confirm that the ONT supports a maximum of eight T-CONTs.

The ONT configuration status fails 4

 

OLT judgment logic:

If the number of T-CONTs reported by the ONT is greater than or equal to the number of T-CONTs reported by the ONT, the OLT determines that the number exceeds the ONT capability set.

Root cause

The number of configured T-CONTs exceeds the maximum capability of the ONT.

 

Solution description

Change the T-CONT range from 0 to 7 and bind the T-CONT to the ONT again. The configuration status is restored.

You are welcome to leave a comment below. Let’s improve our knowledge together! Thank you!