S5730-44C-HI-24S

2 Reviews Write a review
PN02351XFR
AvailabilityIn Stock
Campus Switch S5730-HI
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Original price was: $0.00.Current price is: $0.00.

Huawei S5730-44C-HI-24S switch supports 24 GE SFP ports, 8 of which are dual-purpose 10/100/1000 or SFP ports, 4 10GE SFP+ ports, 2 hot swappable AC/DC power supplies, without power supply equipped

Description

S5730-44C-HI-24S Overview

S5730-44C-HI-24S is a Huawei S5730-HI switch, providing 24 GE SFP ports, 8 of which are dual-purpose 10/100/1,000 Base-T or SFP ports, 4 x 10 GE SFP+ ports, 2 expansion slot, without power module. Huawei S5730-HI gigabit Ethernet switches are Huawei-developed next-generation agile switches that provide fixed full gigabit access and 10 GE uplink interfaces as well as one or two slots for uplink interface extension. The switches are developed based on Huawei Versatile Routing Platform (VRP) to implement software definition and service change on demand. With services and network convergence as the core, the switches provide the free mobility function to ensure consistent user experience. The Super Virtual Fabric (SVF) function virtualizes the entire network into one device. In addition, the switches support flexible Ethernet networking, comprehensive VPN tunnel solutions, various security control methods, intelligent deployment, and simple Operations and Maintenance (O&M). The S5730-HI series switches are the best choices for the access or aggregation layers of medium and large-sized campus networks, and the core layer of branch or small campus networks.

Telecomate.com provides a full range of Huawei switch series, if you have any demands, please contact: csd@telecomate.com

S5730-44C-HI-24S Quick Spec

24 GE SFP ports, 8 of which are dual-purpose 10/100/1,000 Base-T or SFP ports, 4 10 GE SFP+ ports

Switching Capacity is 758 Gbps

S5730-44C-HI-24S appearance and structure

S5730-44C-HI-24S

1 Sixteen 100/1000BASE-X ports 7 One USB port
2 Eight combo ports (10/100/1000BASE-T + 100/1000BASE-X) 8 Ground screw
3 Four 10GE SFP+ ports 9 ESN label
4 One PNP button 10 Rear card slot 1
5 One console port 11 Rear card slot 2
6 One ETH management port 12 Power module slot 2
13 Power module slot 1
S5730-44C-HI-24S Datasheet
Item S5730-44C-HI-24S
Fixed ports 24 GE SFP ports, 8 of which are dual-purpose 10/100/1000 or SFP, 4 10GE SFP+ ports
Extended slot Two extended slots(one of them is reserved), supporting 8-port 10GE electrical, 8-port 10GE optical, or 2-port 40GE optical interface card
Switching capacity 758 Gbit/s
Input voltage AC: Rated AC voltage: 100-240 V AC; 50/60 Hz Max AC voltage: 90-264 V AC; 47-63 Hz DC: Rated DC voltage: -48-60 V DC; Max DC voltage: -38.4-72 V DC
Maximum power consumption (without card) 64 W
Operating temperature 0-1800 m altitude: 0°C to 45°C 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m.
Relative humidity 5% to 95% (non-condensing)
Heat dissipation Air cooling heat dissipation and intelligent speed adjustment
VLAN 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports VLAN mapping
Wireless service AP access control, AP domain management, and AP configuration template management Radio management, unified static configuration, and dynamic centralized management WLAN basic services, QoS, security, and user management CAPWAP, tag/terminal location, and spectrum analysis
Ethernet loop protection RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover SEP ERPS (G.8032) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection
MPLS MPLS L3VPN MPLS L2VPN (VPWS/VPLS) MPLS-TE MPLS QoS
IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy
Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP
IPv6 features Neighbor Discover (ND) PMTU IPv6 Ping, IPv6 Tracert, IPv6 Telnet ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types Multicast Listener Discovery snooping (MLDv1/v2) IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN
Multicast IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM MSDP MVPN
QoS/ACL Rate limitation in the inbound and outbound directions of a port Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port DRR, SP and DRR+SP queue scheduling algorithms WRED Re-marking of the 802.1p and DSCP fields of packets Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Queue-based rate limitation and shaping on ports
Security Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, port number, and VLAN ID Port isolation, port security, and sticky MAC MAC Forced Forwarding (MFF) Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, and HWTACACS authentication NAC SSH V2.0 HTTPS CPU protection Blacklist and whitelist Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets Secure Boot IPSec
Reliability LACP E-trunk Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) ITU-Y.1731 DLDP LLDP BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route
VXLAN Supports VXLAN L2 and L3 gateways Centralized and distributed gateway BGP-EVPN Configured through the NETCONF protocol
Super Virtual Fabric (SVF) Working as an SVF Parent node to vertically virtualize downlink switches and APs as one device for management. A two-layer client architecture is supported. IGMP snooping can be enabled on access switches (ASs) and the maximum number of access users on a port can be configured. ASs can be independently configured. Services that are not supported by templates can be configured on the parent. Third-party devices are allowed between SVF parent and clients. Working as an SVF Client node that is plug-and-play with zero configuration
iPCA Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio Collection of statistics on the number of lost packets and packet loss ratio at network and device levels
TWAMP Two-way IP link performance measurement Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter
Management and maintenance iStack Virtual cable test SNMP v1/v2c/v3 RMON Web-based NMS System logs and alarms of different levels GVRP MUX VLAN 802.3az Energy Efficient Ethernet (EEE) NetStream Dying gasp upon power-off
Dimensions mm (W×D ×H) 442×420×44.4

Additional information

Weight 20.0000 kg
Dimensions 71.5000 × 57.0000 × 23.0000 cm
Campus Switch

S5730-44C-HI-24S Datasheet
Item S5730-44C-HI-24S
Fixed ports 24 GE SFP ports, 8 of which are dual-purpose 10/100/1000 or SFP, 4 10GE SFP+ ports
Extended slot Two extended slots(one of them is reserved), supporting 8-port 10GE electrical, 8-port 10GE optical, or 2-port 40GE optical interface card
Switching capacity 758 Gbit/s
Input voltage AC: Rated AC voltage: 100-240 V AC; 50/60 Hz Max AC voltage: 90-264 V AC; 47-63 Hz DC: Rated DC voltage: -48-60 V DC; Max DC voltage: -38.4-72 V DC
Maximum power consumption (without card) 64 W
Operating temperature 0-1800 m altitude: 0°C to 45°C 1800-5000 m altitude: The operating temperature reduces by 1ºC every time the altitude increases by 220 m.
Relative humidity 5% to 95% (non-condensing)
Heat dissipation Air cooling heat dissipation and intelligent speed adjustment
VLAN 4K VLANs Guest VLAN and voice VLAN GVRP MUX VLAN VLAN assignment based on MAC addresses, protocols, IP subnets, policies, and ports VLAN mapping
Wireless service AP access control, AP domain management, and AP configuration template management Radio management, unified static configuration, and dynamic centralized management WLAN basic services, QoS, security, and user management CAPWAP, tag/terminal location, and spectrum analysis
Ethernet loop protection RRPP ring topology and RRPP multi-instance Smart Link tree topology and Smart Link multi-instance, providing millisecond-level protection switchover SEP ERPS (G.8032) BFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM STP (IEEE 802.1d), RSTP (IEEE 802.1w), and MSTP (IEEE 802.1s) BPDU protection, root protection, and loop protection
MPLS MPLS L3VPN MPLS L2VPN (VPWS/VPLS) MPLS-TE MPLS QoS
IP routing Static routes, RIP v1/2, RIPng, OSPF, OSPFv3, IS-IS, IS-ISv6, BGP, BGP4+, ECMP, routing policy
Interoperability VLAN-Based Spanning Tree (VBST), working with PVST, PVST+, and RPVST Link-type Negotiation Protocol (LNP), similar to DTP VLAN Central Management Protocol (VCMP), similar to VTP
IPv6 features Neighbor Discover (ND) PMTU IPv6 Ping, IPv6 Tracert, IPv6 Telnet ACLs based on source IPv6 addresses, destination IPv6 addresses, Layer 4 ports, or protocol types Multicast Listener Discovery snooping (MLDv1/v2) IPv6 addresses configured for sub-interfaces, VRRP6, DHCPv6, and L3VPN
Multicast IGMP v1/v2/v3 snooping and IGMP fast leave Multicast forwarding in a VLAN and multicast replication between VLANs Multicast load balancing among member ports of a trunk Controllable multicast Port-based multicast traffic statistics IGMP v1/v2/v3, PIM-SM, PIM-DM, and PIM-SSM MSDP MVPN
QoS/ACL Rate limitation in the inbound and outbound directions of a port Packet redirection Port-based traffic policing and two-rate three-color CAR Eight queues on each port DRR, SP and DRR+SP queue scheduling algorithms WRED Re-marking of the 802.1p and DSCP fields of packets Packet filtering at Layer 2 to Layer 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, TCP/UDP port number, protocol type, and VLAN ID Queue-based rate limitation and shaping on ports
Security Hierarchical user management and password protection DoS attack defense, ARP attack defense, and ICMP attack defense Binding of the IP address, MAC address, port number, and VLAN ID Port isolation, port security, and sticky MAC MAC Forced Forwarding (MFF) Blackhole MAC address entries Limit on the number of learned MAC addresses IEEE 802.1x authentication and limit on the number of users on a port AAA authentication, RADIUS authentication, and HWTACACS authentication NAC SSH V2.0 HTTPS CPU protection Blacklist and whitelist Attack source tracing and punishment for IPv6 packets such as ND, DHCPv6, and MLD packets Secure Boot IPSec
Reliability LACP E-trunk Ethernet OAM (IEEE 802.3ah and IEEE 802.1ag) ITU-Y.1731 DLDP LLDP BFD for BGP, BFD for IS-IS, BFD for OSPF, BFD for static route
VXLAN Supports VXLAN L2 and L3 gateways Centralized and distributed gateway BGP-EVPN Configured through the NETCONF protocol
Super Virtual Fabric (SVF) Working as an SVF Parent node to vertically virtualize downlink switches and APs as one device for management. A two-layer client architecture is supported. IGMP snooping can be enabled on access switches (ASs) and the maximum number of access users on a port can be configured. ASs can be independently configured. Services that are not supported by templates can be configured on the parent. Third-party devices are allowed between SVF parent and clients. Working as an SVF Client node that is plug-and-play with zero configuration
iPCA Directly coloring service packets to collect real-time statistics on the number of lost packets and packet loss ratio Collection of statistics on the number of lost packets and packet loss ratio at network and device levels
TWAMP Two-way IP link performance measurement Measurement on two-way packet delay, one-way packet loss rate, and one-way packet jitter
Management and maintenance iStack Virtual cable test SNMP v1/v2c/v3 RMON Web-based NMS System logs and alarms of different levels GVRP MUX VLAN 802.3az Energy Efficient Ethernet (EEE) NetStream Dying gasp upon power-off
Dimensions mm (W×D ×H) 442×420×44.4

Reviews

  1. Haris

    We reveived S5730-44C-HI-24S without any damage on the outside box, brand-new!

  2. Habiba

    We are very angry about this delivery time, almost half a month, much longer than before, because we need it urgent.

Add a review

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart