OSN 9800 U16

2 Reviews Write a review
SKU2012848
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Huawei OptiX OSN 9800 U16 Subrack

Description

OSN 9800 U16 overview

Intended for 100G and beyond 100G optical networks, the OSN 9800 U16 subrack is a next-generation large-capacity OTN product that integrates ASON, OTN, and packet functions. It is applicable to various networks, including super-backbone, backbone, and metro networks.

 

OSN 9800 U16 subrack areas and slots

Boards need to be installed in the designated slots in a subrack. The subrack runs on -48 V DC or -60 V DC and is divided into multiple areas in which designated PIU boards in different slots power boards. The subrack can be installed in an ETSI cabinet or a 19-inch cabinet.

U16 can be used as a service subrack or a central cluster chassis. The function of a U16 subrack depends on the installed system control board. If the TNS1CTU board is installed, the U16 subrack is a common service subrack.

Schematic diagram of the areas and slots in the OptiX OSN 9800 U16 subrack (central cluster chassis)Descriptions of the areas and slots in the OptiX OSN 9800 U16 subrack (service subrack)

Descriptions of the areas and slots in the OptiX OSN 9800 U16 subrack (service subrack)

Area Composition Slot Function
System control and cross-connect board area 4 PIU boards IU68, IU69, IU80, IU81 They supply power to the subrack.
The PIU boards in slots IU68 and IU80, and the PIU boards in slots IU69 and IU81 are in mutual backup. Therefore, the failure of any power input to the subrack does not affect the normal operation of the subrack.
1 EFI board IU79 The EFI board provides maintenance and management interfaces.
2 CTU boards (TNS1CTU) IU70, IU78 The CTU boards manage the subrack, provide a clock for service boards, and implement inter-NE communication.
Two CTU boards are configured for mutual backup.
7 cross-connect boards (TNS1XCS/TNS1UXCS) IU71-IU77 The cross-connect boards’ groom services between service boards.
Cross-connect boards are configured in M: N backup mode.
When a U16 subrack is used as a pure regeneration subrack, no cross-connect board is required.
Fan area 2 fan tray assemblies IU90, IU91 Fan tray assemblies are used to ventilate the equipment.
Fiber-routing areas 2 fiber troughs N/A Fiber patch cords connecting to boards are routed to the left or right side of the equipment through the upper- and lower-side fiber troughs.
Service board area 14 service boards IU1-IU14 Service boards need to be configured based on the service plan and all of them are installed in the service board area.

 

Descriptions of the areas and slots in the OptiX OSN 9800 U16 subrack (central cluster chassis)

Area Composition Slot Function
System clock and control board area 4 PIU boards IU68, IU69, IU80, IU81 They supply power to the subrack.
The PIU boards in slots IU68 and IU80, and the PIU boards in slots IU69 and IU81 are in mutual backup. Therefore, the failure of any power input to the subrack does not affect the normal operation of the subrack.
1 EFI board IU79 The EFI board provides maintenance and management interfaces.
2 CTU boards (TNS2CTU) IU70, IU78 The CTU boards manage the subrack, provide a clock for service boards, and implement inter-NE communication.
Two CTU boards are configured for mutual backup.
2 system clock distribution boards (TNS1Std) IU75, IU77 Implements system clock processing and distribution for a cluster.
Fan tray assemblies are used to ventilate the equipment.
Fiber patch cords connecting to boards are routed to the left or right side of the equipment through the upper- and lower-side fiber troughs.
Cluster cross-connect board area 14 cross-connect boards (TNU1CCXCS) IU1-IU14 Implements centralized grooming of inter-subrack services for a cluster.

 

OSN 9800 U16 cross-connect capacities

This topic describes the maximum cross-connect capacity of a service slot and an OptiX OSN 9800 U16 subrack.

When an OptiX OSN 9800 U16 subrack functions as a service subrack: An OptiX OSN 9800 U16 subrack supports grooming of ODUk (k = 0, 1, 2, 2e, 3, 4, flex) services, packet services, and VC-3/VC-4/VC-12 services. Slots IU1-IU14 provide the same cross-connect capacity.

Maximum Cross-Connect Capacity of Each Slot Maximum Cross-Connect Capacity of Each Subrack
ODUk VC-4 VC-3/VC-12a Packet ODUk VC-4 VC-3/VC-12 Packet
400 Gbit/s 80 Gbit/s 80 Gbit/s 200 Gbit/s 5.6 Tbit/s 1.12 Tbit/s 80 Gbit/s 2.8 Tbit/s
a: All service slots share a bandwidth of 80 Gbit/s.