Description
OSN 9800 M24/M12/M05 overview
The next-generation M series subracks feature large capacity, optical-electrical integration, and small size. The M series subracks apply to integrated bearing scenarios, such as broadband video, mobile backhaul, private enterprise line, and DCI, and provide an optimal end-to-end transmission solution from the backbone layer, aggregation layer, to the access layer.
The specifications are as follows:
Specifications | OSN9800 M24 | OSN9800 M12 | OSN9800 M05 |
Product Appearance | |||
Subrack dimensions (mm) | 747.2 (H) x 442 (W) x 295 (D) | 347.2 (H) x 442 (W) x 295 (D) | 177 (H) x 442 (W) x 295 (D) |
Suitable cabinet | ETSI 300/600 cabinets, such as the A63B 19-inch cabinet | ||
Max. number of service board slots | 1:1 cross-connect mode: 12 large slots or 24 small slots 1:3 cross-connect mode: 10 large slots or 20 small slots NOTE: The M24 subrack supports slot splitting. One 11 U slot of the M24 subrack can be split into two 5.5 U slots. | 13 | 5 |
Switching capability | Optical: 1 to 20-degree reconfigurable optical add/drop multiplexer (ROADM) | ||
Electrical: 1:1 cross-connect mode: 4.8 Tbit/s OSUflex/ODUk 4.8 Tbit/s packet services 1.92 Tbit/s VC-4 160 Gbit/s VC-3/VC-12 1:3 cross-connect mode: 10 Tbit/s OSUflex/ODUk 4 Tbit/s packet services 1.6 Tbit/s VC-4 160 Gbit/s VC-3/VC-12 | N/A | ||
Max. number of wavelengths | Fixed grid: 120 wavelengths@50 GHz grid Flexible grid: The maximum number of wavelengths is related to the width of the flex channel. | ||
Wavelength range | DWDM system: 1524.50 nm to 1572.06 nm (Super C band) CWDM system: 1471 nm to 1611 nm (S+C+L band) | ||
Max. rate per channel | 800 Gbit/s (OTUC8) | ||
Service type | SDH, SONET, PDH, Ethernet, SAN, OTN, Video | SDH, SONET, Ethernet, SAN, OTN, Video | |
Packet service capacity | Support for E-Line/E-LAN (MEF) and VPWS/VPLS (IETF) Support for MPLS-TP Number of MPLS tunnels: 64 x 1024 Number of PWs: 64 x 1024 Number of E-Line services: 32 x 1024 Number of E-LAN services: 8 x 1024 | N/A | |
Line rate | 1.25 Gbit/s, 2.5 Gbit/s, 10 Gbit/s, 25 Gbit/s, 100 Gbit/s, 200G bit/s, 400G bit/s, 600G bit/s, 800G bit/s | 10 Gbit/s, 100 Gbit/s, 200G bit/s, 400G bit/s, 600G bit/s, 800G bit/s | |
Supported pluggable optical modules | eSFP, SFP+, TSFP+, CFP, CSFP, CFP2, QSFP28, SFP28, TSFP28, QSFP+, QSFP-DD | eSFP, SFP+, TSFP+, CFP, CSFP, CFP2, QSFP28, SFP28, QSFP+, QSFP-DD | |
Topology | Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh | ||
Redundancy and protection | Network level protection (OTN): Optical line protection, client 1+1 protection, ODUk SNCP, OSUflex SNCP, tributary SNCP, intra-board 1+1 protection, LPT | Optical line protection, client 1+1 protection, intra-board 1+1 protection, LPT, ODUk SNCP, tributary SNCP | |
Network level protection (Packet): ERPS, LAG, PW APS/FPS, Tunnel APS, MC-LAG, MC-PW APS, LPT | N/A | ||
Network Level Protection (SDH): SNCP, linear MSP, ring MSP, TPS | N/A | ||
Network level protection (EoS): LAG, DLAG, LCAS, LPT, STP/RSTP, BPS, PPS | N/A | ||
Equipment level protection: Power supply redundancy, fan redundancy, cross-connect board redundancy, communication control, and clock processing unit redundancy | Power supply redundancy, fan redundancy, communication control unit redundancy, clock processing unit redundancy | ||
Optical power management | ALS, ALC, IPA, IPA of the Raman system, IPC | ||
Easy O&M | Visual Doctor (OD) system, Fiber Doctor (FD) system | ||
Synchronization | Synchronous Ethernet, IEEE 1588v2, ITU-T G.8275.1/G.8273.2, high-precision clock synchronization | ||
ASON | Electrical-layer ASON Optical-layer ASON SDH ASON 2M ASON Fast E2E Service Provisioning | Optical-layer ASON | |
TSDN | Fast E2E Service Provisioning Bandwidth Adjustment Scheduled Service Provisioning Resource Usage View Latency Map | ||
Submarine cable features | Supports the application of extended C band in submarine cable scenarios. | N/A | N/A |
Power supply | DC power input | ||
Operation environment | Subrack temperature: Long-term operation: 0°C to 45°C Short-term process: –5°C to +50°C Relative humidity: Long-term process: 5% to 85% Short-term operation: 5% to 90% | Subrack temperature: Long-term process: 0°C to 45°C Short-term process: –5°C to +55°C Relative humidity: Long-term process: 5% to 85% Short-term operation: 5% to 90% | Subrack temperature: Long-term process: 0°C to 50°C Short-term process: –5°C to +55°C Relative humidity: Long-term process: 5% to 85% Short-term operation: 5% to 90% |
Mean Time To Repair (MTtr) | 1 hour
NOTE: Average time for fault locating, board replacement, device restart, and service recovery, excluding component preparation and transportation time. |
||
Mean Time Between Failure (MTBF) | 65.94 years | ||
Availability | 0.999993076c | ||
a: The ETSI/19-inch standard defines only part of the cabinet dimensions. Therefore, the distance between the cabinet column and door plate varies depending on cabinet manufacturers. For details about the dimensions of different subracks, see the detailed description of each subrack. | |||
b: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days. | |||
c: The preceding parameters are calculated based on the typical product configuration. In actual use, these parameters vary according to the configured module. |
Supported Services Capabilities (OSN9800 M24/M12/M05)
Service Category | Service Type | Max. Number of Service Inputs Supported by the 9800 M24 Subrack | Max. Number of Service Inputs Supported by the 9800 M12 Subrack | Max. Number of Service Inputs Supported by the 9800 M05 Subrack |
SDH | STM-1 | 360 | 156 | 60 |
STM-4 | 360 | 156 | 60 | |
STM-16 | 360 | 156 | 60 | |
STM-64 | 360 | 156 | 60 | |
SONET | OC-3 | 360 | 156 | 60 |
OC-12 | 360 | 156 | 60 | |
OC-48 | 360 | 156 | 60 | |
OC-192 | 360 | 156 | 60 | |
PDH | E1 | 128 | N/A | N/A |
T1 | 128 | N/A | N/A | |
Ethernet service | FE (optical signal) | 360 | 156 | 60 |
GE (optical signal) | 360 | 156 | 60 | |
GE (electrical signal) | 360a | 156a | 60a | |
10GE WAN | 360 | 156 | 60 | |
10GE LAN | 480 | 260 | 100 | |
25GE | 192 | 104 | 40 | |
40GE | 100 | 52 | 20 | |
50GE | 48 | 26 | 10 | |
100GE | 192 | 104 | 40 | |
200GE | 96 | 52 | 20 | |
400GE | 48 | 26 | 10 | |
Flexible Ethernet service (FlexE) | FlexE Unaware (50G) | 24 | N/A | N/A |
FlexE Unaware (100G) | 192 | 104 | 40 | |
FlexE Aware (200G) | 24 | N/A | N/A | |
FlexE Unaware (200G) | 96 | 52 | 20 | |
FlexE Unaware (400G) | 24 | 13 | 5 | |
SAN service | FDDI | 360 | 156 | 60 |
ESCON | 360 | 156 | 60 | |
FC100/FICON | 360 | 156 | 60 | |
FC200/FICON Express | 360 | 156 | 60 | |
FC400/FICON4G | 360 | 156 | 60 | |
FC800/FICON8G | 360 | 156 | 60 | |
FC1200/FICON 10G | 360 | 156 | 60 | |
FC1600 | 192 | 104 | 40 | |
FC1600-trunk-2 | 96 | 52 | 20 | |
FC1600-trunk-4 | 48 | 26 | 10 | |
FC3200 | 96 | 52 | 20 | |
OTN service | OTU1 | 360 | 156 | 60 |
OTU2 | 360 | 156 | 60 | |
OTU2e | 360 | 156 | 60 | |
OTU4 | 144 | 144 | 30 | |
Video service | DVB-ASI | 360 | 156 | 60 |
SD-SDI | 360 | 156 | 60 | |
HD-SDIa | 360 | 156 | 60 | |
HD-SDIRBR | 360 | 156 | 60 | |
3G-SDIa | 360 | 156 | 60 | |
3G-SDIRBR | 360 | 156 | 60 | |
a: This value only refers to the maximum tributary service capacity when the subrack is fully configured with tributary boards but with no line boards. |
mark –
I bought one for trial, and everything was good.
Sophia –
The device supports multiple transmission rates, including 10G, 40G, and 100G, and is easy to expand in the future, reducing upgrade costs.