OSN 9800 M24/M12/M05

2 Reviews Write a review
SKU2013054
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Huawei OptiX OSN 9800 M24/M12/M05 Subrack

Description

OSN 9800 M24/M12/M05 overview

 

The next-generation M series subracks feature large capacity, optical-electrical integration, and small size. The M series subracks apply to integrated bearing scenarios, such as broadband video, mobile backhaul, private enterprise line, and DCI, and provide an optimal end-to-end transmission solution from the backbone layer, aggregation layer, to the access layer.

The specifications are as follows:

Specifications OSN9800 M24 OSN9800 M12 OSN9800 M05
Product Appearance  OSN9800 M24 OSN9800 M12 OSN9800 M05
Subrack dimensions (mm) 747.2 (H) x 442 (W) x 295 (D) 347.2 (H) x 442 (W) x 295 (D) 177 (H) x 442 (W) x 295 (D)
Suitable cabinet ETSI 300/600 cabinets, such as the A63B 19-inch cabinet
Max. number of service board slots 1:1 cross-connect mode: 12 large slots or 24 small slots 1:3 cross-connect mode: 10 large slots or 20 small slots NOTE: The M24 subrack supports slot splitting. One 11 U slot of the M24 subrack can be split into two 5.5 U slots. 13 5
Switching capability Optical: 1 to 20-degree reconfigurable optical add/drop multiplexer (ROADM)
Electrical: 1:1 cross-connect mode: 4.8 Tbit/s OSUflex/ODUk 4.8 Tbit/s packet services 1.92 Tbit/s VC-4 160 Gbit/s VC-3/VC-12 1:3 cross-connect mode: 10 Tbit/s OSUflex/ODUk 4 Tbit/s packet services 1.6 Tbit/s VC-4 160 Gbit/s VC-3/VC-12 N/A
Max. number of wavelengths Fixed grid: 120 wavelengths@50 GHz grid Flexible grid: The maximum number of wavelengths is related to the width of the flex channel.
Wavelength range DWDM system: 1524.50 nm to 1572.06 nm (Super C band) CWDM system: 1471 nm to 1611 nm (S+C+L band)
Max. rate per channel 800 Gbit/s (OTUC8)
Service type SDH, SONET, PDH, Ethernet, SAN, OTN, Video SDH, SONET, Ethernet, SAN, OTN, Video
Packet service capacity Support for E-Line/E-LAN (MEF) and VPWS/VPLS (IETF) Support for MPLS-TP Number of MPLS tunnels: 64 x 1024 Number of PWs: 64 x 1024 Number of E-Line services: 32 x 1024 Number of E-LAN services: 8 x 1024 N/A
Line rate 1.25 Gbit/s, 2.5 Gbit/s, 10 Gbit/s, 25 Gbit/s, 100 Gbit/s, 200G bit/s, 400G bit/s, 600G bit/s, 800G bit/s 10 Gbit/s, 100 Gbit/s, 200G bit/s, 400G bit/s, 600G bit/s, 800G bit/s
Supported pluggable optical modules eSFP, SFP+, TSFP+, CFP, CSFP, CFP2, QSFP28, SFP28, TSFP28, QSFP+, QSFP-DD eSFP, SFP+, TSFP+, CFP, CSFP, CFP2, QSFP28, SFP28, QSFP+, QSFP-DD
Topology Point-to-point, chain, star, ring, ring-with-chain, tangent ring, intersecting ring, and mesh
Redundancy and protection Network level protection (OTN): Optical line protection, client 1+1 protection, ODUk SNCP, OSUflex SNCP, tributary SNCP, intra-board 1+1 protection, LPT Optical line protection, client 1+1 protection, intra-board 1+1 protection, LPT, ODUk SNCP, tributary SNCP
Network level protection (Packet): ERPS, LAG, PW APS/FPS, Tunnel APS, MC-LAG, MC-PW APS, LPT N/A
Network Level Protection (SDH): SNCP, linear MSP, ring MSP, TPS N/A
Network level protection (EoS): LAG, DLAG, LCAS, LPT, STP/RSTP, BPS, PPS N/A
Equipment level protection: Power supply redundancy, fan redundancy, cross-connect board redundancy, communication control, and clock processing unit redundancy Power supply redundancy, fan redundancy, communication control unit redundancy, clock processing unit redundancy
Optical power management ALS, ALC, IPA, IPA of the Raman system, IPC
Easy O&M Visual Doctor (OD) system, Fiber Doctor (FD) system
Synchronization Synchronous Ethernet, IEEE 1588v2, ITU-T G.8275.1/G.8273.2, high-precision clock synchronization
ASON Electrical-layer ASON Optical-layer ASON SDH ASON 2M ASON Fast E2E Service Provisioning Optical-layer ASON
TSDN Fast E2E Service Provisioning Bandwidth Adjustment Scheduled Service Provisioning Resource Usage View Latency Map
Submarine cable features Supports the application of extended C band in submarine cable scenarios. N/A N/A
Power supply DC power input
Operation environment Subrack temperature: Long-term operation: 0°C to 45°C Short-term process: –5°C to +50°C Relative humidity: Long-term process: 5% to 85% Short-term operation: 5% to 90% Subrack temperature: Long-term process: 0°C to 45°C Short-term process: –5°C to +55°C Relative humidity: Long-term process: 5% to 85% Short-term operation: 5% to 90% Subrack temperature: Long-term process: 0°C to 50°C Short-term process: –5°C to +55°C Relative humidity: Long-term process: 5% to 85% Short-term operation: 5% to 90%
Mean Time To Repair (MTtr) 1 hour

NOTE: Average time for fault locating, board replacement, device restart, and service recovery, excluding component preparation and transportation time.

Mean Time Between Failure (MTBF) 65.94 years
Availability 0.999993076c
a: The ETSI/19-inch standard defines only part of the cabinet dimensions. Therefore, the distance between the cabinet column and door plate varies depending on cabinet manufacturers. For details about the dimensions of different subracks, see the detailed description of each subrack.
b: Short-term operation means that the continuous operating time does not exceed 96 hours and the accumulated time per year does not exceed 15 days.
c: The preceding parameters are calculated based on the typical product configuration. In actual use, these parameters vary according to the configured module.

 

Supported Services Capabilities (OSN9800 M24/M12/M05)

Service Category Service Type Max. Number of Service Inputs Supported by the 9800 M24 Subrack Max. Number of Service Inputs Supported by the 9800 M12 Subrack Max. Number of Service Inputs Supported by the 9800 M05 Subrack
SDH STM-1 360 156 60
STM-4 360 156 60
STM-16 360 156 60
STM-64 360 156 60
SONET OC-3 360 156 60
OC-12 360 156 60
OC-48 360 156 60
OC-192 360 156 60
PDH E1 128 N/A N/A
T1 128 N/A N/A
Ethernet service FE (optical signal) 360 156 60
GE (optical signal) 360 156 60
GE (electrical signal) 360a 156a 60a
10GE WAN 360 156 60
10GE LAN 480 260 100
25GE 192 104 40
40GE 100 52 20
50GE 48 26 10
100GE 192 104 40
200GE 96 52 20
400GE 48 26 10
Flexible Ethernet service (FlexE) FlexE Unaware (50G) 24 N/A N/A
FlexE Unaware (100G) 192 104 40
FlexE Aware (200G) 24 N/A N/A
FlexE Unaware (200G) 96 52 20
FlexE Unaware (400G) 24 13 5
SAN service FDDI 360 156 60
ESCON 360 156 60
FC100/FICON 360 156 60
FC200/FICON Express 360 156 60
FC400/FICON4G 360 156 60
FC800/FICON8G 360 156 60
FC1200/FICON 10G 360 156 60
FC1600 192 104 40
FC1600-trunk-2 96 52 20
FC1600-trunk-4 48 26 10
FC3200 96 52 20
OTN service OTU1 360 156 60
OTU2 360 156 60
OTU2e 360 156 60
OTU4 144 144 30
Video service DVB-ASI 360 156 60
SD-SDI 360 156 60
HD-SDIa 360 156 60
HD-SDIRBR 360 156 60
3G-SDIa 360 156 60
3G-SDIRBR 360 156 60
a: This value only refers to the maximum tributary service capacity when the subrack is fully configured with tributary boards but with no line boards.
Supported Services Types (OSN 9800 M24/M12/M05)   Service types, service rates, and corresponding service boards supported by the 9800 M12/M05 Subrack
Service Category Service Type Service Rate Board Standards Compliance
SDH STM-1 155.52 Mbit/s M210D, M520SM, SL16Q, SL41O, SL64D, M520S ITU-T G.707 ITU-T G.691 ITU-T G.957 ITU-T G.693 ITU-T G.783 ITU-T G.825
STM-4 622.08 Mbit/s
STM-16 2.5 Gbit/s
STM-64 9.95 Gbit/s
SONET OC-3 155.52 Mbit/s M210D, M520SM, M520S GR-253-CORE GR-1377-CORE ANSI T1.105
OC-12 622.08 Mbit/s
OC-48 2.5 Gbit/s
OC-192 9.95 Gbit/s
Ethernet service FE (optical signal) Interface rate: 125 Mbit/s M210D, M520SM, M520S, G1EMS12, V1EMS12 IEEE 802.3u
Service rate: 100 Mbit/s
GE (optical signal) Interface rate: 1.25 Gbit/s IEEE 802.3z
Service rate: 1 Gbit/s
GE (electrical signal) Interface rate: 1.25 Gbit/s
Service rate: 1 Gbit/s
10GE WAN 9.95 Gbit/s IEEE 802.3ae
10GE LAN 10.31 Gbit/s M210D, M404DM, M502DM, M504DM, M520SM, TNG2M604SM, M520S, G1EMS12, V1EMS12
25GE 25.78 Gbit/s M520SM, M520S IEEE 802.3by
40GE 41.25 Gbit/s M404DM, M504DM, M520SM, M604SM, M520S IEEE 802.3ba
50GE 51.5625 Gbit/s M520SM, M520S
100GE 103.125 Gbit/s M402, M502DM, M504DM, M520SM, M604SM, TNG1M604S, TNG1M804SM, TNG2M504S, G3M402D, G3M504D, M520S
200GE 206.25Gbit/s TNG1M804SM
400GE 425 Gbit/s TNG1M804SM,TNG1M604S
Flex Ethernet service (FlexE) FlexE 100G unaware 103.125 Gbit/s TNG1M804SM, TNG2M504DM IA Flex Ethernet 2.1
FlexE 200G unaware 206.25 Gbit/s TNG1M804SM
FlexE 400G unaware 425 Gbit/s TNG3M504SP
SAN service FDDI 125 Mbit/s M210D, M520SM, M520S ANSI X3.296 ANSI X3.230 ANSI X3.303
ESCON 200 Mbit/s
FC100/FICON 1.06 Gbit/s
FC200/FICON Express 2.12 Gbit/s
FC400/FICON4G 4.25 Gbit/s
FC800/FICON8G 8.5 Gbit/s
FC1200/FICON10G 10.51 Gbit/s
FC1600 14.025 Gbit/s M520SM, M520S
FC1600-trunk-2 2 X 14.025Gbit/s
FC1600-trunk-4 4 X 14.025Gbit/s
FC3200 28.05 Gbit/s
OTN service OTU1 2.67 Gbit/s M210D, M520SM, M520S ITU-T G.709 ITU-T G.959.1 GR-2918-CORE
OTU2 10.71 Gbit/s
OTU2e 11.10 Gbit/s
OTU4 111.81 Gbit/s M402, M502DM, M504DM, M520SM, M604SM, TNG1M804SM, G3M402D, G3M504D, M520S
Video service DVB-ASI 270 Mbit/s M210D, M520SM, M520S EN 50083-9
SD-SDI 270 Mbit/s SMPTE 259M
HD-SDIa 1.49 Gbit/s SMPTE 292M
HD-SDIRBR 1.49/1.001 Gbit/s
3G-SDIa 2.97 Gbit/s SMPTE 424M
3G-SDIRBR 2.97/1.001 Gbit/s
GE: Gigabit Ethernet
ESCON: enterprise system connection
FICON: Fibre Connect
FC: fiber channel
DVB-ASI: digital video broadcast-asynchronous serial interface
SD-SDI: standard definition-serial digital interface signal. For SMPTE-259M specifically, SD-SDI is also called SDI.
a: According to SMPTE 292M standards, HD-SDI and 3G-SDI have two rates. The rates of HD-SDI are 1.485 Gbit/s and 1.485/1.001 Gbit/s, and those of 3G-SDI are 2.97 Gbit/s and 2.97/1.001 Gbit/s. The 1/1.001 factor is the parameter that complies with National Transportation Safety Committee (NTSC) standards. NTSC is the analog television system widely used in North America, some Latin America regions, South Korea, Japan, and some Pacific island nations and territories.
Service types, service rates, and corresponding service boards supported by the 9800 M24 Subrack
Service Category Service Type Service Rate Board Standards Compliance
SDH STM-1 (optical signal) 155.52 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, S216, M210D, M520SM, TNV6G216, G230, M520S ITU-T G.707 ITU-T G.691 ITU-T G.957 ITU-T G.693 ITU-T G.783 ITU-T G.825
STM-1 (electrical signal) 155.52 Mbit/s TNV6S216
STM-4 622.08 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, S216, M210D, M520SM, TNV6G216, G230, M520S
STM-16 2.5 Gbit/s
STM-64 9.95 Gbit/s
SONET OC-3 155.52 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230, M520S GR-253-CORE GR-1377-CORE ANSI T1.105
OC-12 622.08 Mbit/s
OC-48 2.5 Gbit/s
OC-192 9.95 Gbit/s
PDH E1 2.048 Mbit/s TNG1TPS, TNG1DMS, TNG1PD1 ITU-T G.703 ITU-T G.823 ITU-T G.783 ITU-T G.824 ITU-T G.742
T1 1.544 Mbit/s TNG1TPS, TNG1DMS, TNG1PD1 ITU-T G.703 ITU-T G.823 ITU-T G.824 ITU-T G.783
Ethernet service FE (optical signal) Interface rate: 125 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, E224, EMS20, M210D, M520SM, TNV3T220E, TNV6G216, G230, M520S, V1EMS12, G1EMS12, G1EFS8, G1EGS4 IEEE 802.3u
Service rate: 100 Mbit/s
GE (optical signal) Interface rate: 1.25 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, E224, EMS20, M210D, M520SM, TNV3T220E, TNV6G216, G230, M520S, V1EMS12, G1EMS12, G1EGS4 IEEE 802.3z
Service rate: 1 Gbit/s
GE (electrical signal) Interface rate: 1.25 Gbit/s IEEE 802.3ab
Service rate: 1 Gbit/s
10GE WAN 9.95 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230, M520S IEEE 802.3ae
10GE LAN 10.31 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, E224, EMS20, M404DM, M502DM, M504DM, M210D, M520SM, TNV3T220E, TNG2M504S, TNG2M604SM, TNV6G216, G230, M520S
25GE 25.78 Gbit/s TNV7T220, T216, TNV6T230, TNV3E224, M520SM, TNV6G216, G230, M520S IEEE 802.3by
40GE 41.25 Gbit/s TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T410, T502, M404DM, M504DM, M520SM, M604SM, TNG2M504S, M520S IEEE 802.3ba
50GE 51.5625 Gbit/s T502, TNV3E402, M520SM, TNV3E404, M520S
100GE 103.125 Gbit/s G402, G404, TNG1T401, TNV3T401, TNV3T404, TNV3T402, TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T410, T502, E402, M402, M502DM, M504DM, M520SM, M604SM,TNG1M604S, TNG1M804SM, TNG2M504S, G3M402D, G3M504D, M520S
200GE 206.25 Gbit/s T502, TNG1M804SM
400GE 412.5 Gbit/s T601,TNG1M604S,TNG1M804SM
Flex Ethernet service (FlexE) FlexE Unaware (50G) 51.5625 Gbit/s T502 IA Flex Ethernet 2.1
FlexE Unaware (100G) 103.125 Gbit/s TNV8T402, TNV8T404, T502,TNG1M804SM, TNV5T401, TNV5T402,TNV7T402, TNV5T404, TNV1T410, TNG2M504DM
FlexE Unaware (200G) 206.25 Gbit/s TNG1M804SM
FlexE Aware (200G) 206.25 Gbit/s T502
FlexE Unaware (400G) 425 Gbit/s TNG3M504SP
SAN service FDDI 125 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230 , M520S ANSI X3.296 ANSI X3.230 ANSI X3.303
ESCON 200 Mbit/s
FC100/FICON 1.06 Gbit/s
FC200/FICON Express 2.12 Gbit/s
FC400/FICON4G 4.25 Gbit/s
FC800/FICON8G 8.5 Gbit/s
FC1200/FICON 10G 10.51 Gbit/s
FC1600 14.025 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, M520SM, TNV6G216, G230, M520S
FC1600-trunk-2 2 X 14.025Gbit/s M520SM, M520S
C1600-trunk-4 4 X 14.025Gbit/s
FC3200 28.05 Gbit/s T216, TNV7T220, TNV6T230, M520SM, TNV6G216, G230, M520S
OTN service OTU1 2.67 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV3S216, TNV4S216, TNV6G216, G230, M520S ITU-T G.709 ITU-T G.959.1 GR-2918-CORE
OTU2 10.71 Gbit/s
OTU2e 11.10 Gbit/s
OTU4 111.81 Gbit/s G402, G404, M402, TNG1T401, TNV3T401, TNV3T402, TNV3T404, TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T410, T502, M502DM, M504DM, M520SM, M604SM, TNG2M504S,TNG1M804SM, G3M402D, G3M504D, M520S
Video service DVB-ASI 270 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230, M520S EN 50083-9
SD-SDI 270 Mbit/s SMPTE 259M
HD-SDIa 1.49 Gbit/s SMPTE 292M
HD-SDIRBR 1.49/1.001 Gbit/s
3G-SDIa 2.97 Gbit/s SMPTE 424M
3G-SDIRBR 2.97/1.001 Gbit/s
GE: Gigabit Ethernet
ESCON: enterprise system connection
FICON: Fibre Connect
FC: fiber channel
DVB-ASI: digital video broadcast-asynchronous serial interface
SD-SDI: standard definition-serial digital interface signal. For SMPTE-259M specifically, SD-SDI is also called SDI.
a: According to SMPTE 292M standards, both HD-SDI and 3G-SDI have two rates. The rates of HD-SDI are 1.485 Gbit/s and 1.485/1.001 Gbit/s, and those of 3G-SDI are 2.97 Gbit/s and 2.97/1.001 Gbit/s. The 1/1.001 factor is the parameter that complies with National Transportation Safety Committee (NTSC) standards. NTSC is the analog television system that is widely used in North America, some Latin America regions, South Korea, Japan, and some Pacific island nations and territories.

Additional information

Supported Services Types (OSN 9800 M24/M12/M05)   Service types, service rates, and corresponding service boards supported by the 9800 M12/M05 Subrack
Service Category Service Type Service Rate Board Standards Compliance
SDH STM-1 155.52 Mbit/s M210D, M520SM, SL16Q, SL41O, SL64D, M520S ITU-T G.707 ITU-T G.691 ITU-T G.957 ITU-T G.693 ITU-T G.783 ITU-T G.825
STM-4 622.08 Mbit/s
STM-16 2.5 Gbit/s
STM-64 9.95 Gbit/s
SONET OC-3 155.52 Mbit/s M210D, M520SM, M520S GR-253-CORE GR-1377-CORE ANSI T1.105
OC-12 622.08 Mbit/s
OC-48 2.5 Gbit/s
OC-192 9.95 Gbit/s
Ethernet service FE (optical signal) Interface rate: 125 Mbit/s M210D, M520SM, M520S, G1EMS12, V1EMS12 IEEE 802.3u
Service rate: 100 Mbit/s
GE (optical signal) Interface rate: 1.25 Gbit/s IEEE 802.3z
Service rate: 1 Gbit/s
GE (electrical signal) Interface rate: 1.25 Gbit/s
Service rate: 1 Gbit/s
10GE WAN 9.95 Gbit/s IEEE 802.3ae
10GE LAN 10.31 Gbit/s M210D, M404DM, M502DM, M504DM, M520SM, TNG2M604SM, M520S, G1EMS12, V1EMS12
25GE 25.78 Gbit/s M520SM, M520S IEEE 802.3by
40GE 41.25 Gbit/s M404DM, M504DM, M520SM, M604SM, M520S IEEE 802.3ba
50GE 51.5625 Gbit/s M520SM, M520S
100GE 103.125 Gbit/s M402, M502DM, M504DM, M520SM, M604SM, TNG1M604S, TNG1M804SM, TNG2M504S, G3M402D, G3M504D, M520S
200GE 206.25Gbit/s TNG1M804SM
400GE 425 Gbit/s TNG1M804SM,TNG1M604S
Flex Ethernet service (FlexE) FlexE 100G unaware 103.125 Gbit/s TNG1M804SM, TNG2M504DM IA Flex Ethernet 2.1
FlexE 200G unaware 206.25 Gbit/s TNG1M804SM
FlexE 400G unaware 425 Gbit/s TNG3M504SP
SAN service FDDI 125 Mbit/s M210D, M520SM, M520S ANSI X3.296 ANSI X3.230 ANSI X3.303
ESCON 200 Mbit/s
FC100/FICON 1.06 Gbit/s
FC200/FICON Express 2.12 Gbit/s
FC400/FICON4G 4.25 Gbit/s
FC800/FICON8G 8.5 Gbit/s
FC1200/FICON10G 10.51 Gbit/s
FC1600 14.025 Gbit/s M520SM, M520S
FC1600-trunk-2 2 X 14.025Gbit/s
FC1600-trunk-4 4 X 14.025Gbit/s
FC3200 28.05 Gbit/s
OTN service OTU1 2.67 Gbit/s M210D, M520SM, M520S ITU-T G.709 ITU-T G.959.1 GR-2918-CORE
OTU2 10.71 Gbit/s
OTU2e 11.10 Gbit/s
OTU4 111.81 Gbit/s M402, M502DM, M504DM, M520SM, M604SM, TNG1M804SM, G3M402D, G3M504D, M520S
Video service DVB-ASI 270 Mbit/s M210D, M520SM, M520S EN 50083-9
SD-SDI 270 Mbit/s SMPTE 259M
HD-SDIa 1.49 Gbit/s SMPTE 292M
HD-SDIRBR 1.49/1.001 Gbit/s
3G-SDIa 2.97 Gbit/s SMPTE 424M
3G-SDIRBR 2.97/1.001 Gbit/s
GE: Gigabit Ethernet
ESCON: enterprise system connection
FICON: Fibre Connect
FC: fiber channel
DVB-ASI: digital video broadcast-asynchronous serial interface
SD-SDI: standard definition-serial digital interface signal. For SMPTE-259M specifically, SD-SDI is also called SDI.
a: According to SMPTE 292M standards, HD-SDI and 3G-SDI have two rates. The rates of HD-SDI are 1.485 Gbit/s and 1.485/1.001 Gbit/s, and those of 3G-SDI are 2.97 Gbit/s and 2.97/1.001 Gbit/s. The 1/1.001 factor is the parameter that complies with National Transportation Safety Committee (NTSC) standards. NTSC is the analog television system widely used in North America, some Latin America regions, South Korea, Japan, and some Pacific island nations and territories.
Service types, service rates, and corresponding service boards supported by the 9800 M24 Subrack
Service Category Service Type Service Rate Board Standards Compliance
SDH STM-1 (optical signal) 155.52 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, S216, M210D, M520SM, TNV6G216, G230, M520S ITU-T G.707 ITU-T G.691 ITU-T G.957 ITU-T G.693 ITU-T G.783 ITU-T G.825
STM-1 (electrical signal) 155.52 Mbit/s TNV6S216
STM-4 622.08 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, S216, M210D, M520SM, TNV6G216, G230, M520S
STM-16 2.5 Gbit/s
STM-64 9.95 Gbit/s
SONET OC-3 155.52 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230, M520S GR-253-CORE GR-1377-CORE ANSI T1.105
OC-12 622.08 Mbit/s
OC-48 2.5 Gbit/s
OC-192 9.95 Gbit/s
PDH E1 2.048 Mbit/s TNG1TPS, TNG1DMS, TNG1PD1 ITU-T G.703 ITU-T G.823 ITU-T G.783 ITU-T G.824 ITU-T G.742
T1 1.544 Mbit/s TNG1TPS, TNG1DMS, TNG1PD1 ITU-T G.703 ITU-T G.823 ITU-T G.824 ITU-T G.783
Ethernet service FE (optical signal) Interface rate: 125 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, E224, EMS20, M210D, M520SM, TNV3T220E, TNV6G216, G230, M520S, V1EMS12, G1EMS12, G1EFS8, G1EGS4 IEEE 802.3u
Service rate: 100 Mbit/s
GE (optical signal) Interface rate: 1.25 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, E224, EMS20, M210D, M520SM, TNV3T220E, TNV6G216, G230, M520S, V1EMS12, G1EMS12, G1EGS4 IEEE 802.3z
Service rate: 1 Gbit/s
GE (electrical signal) Interface rate: 1.25 Gbit/s IEEE 802.3ab
Service rate: 1 Gbit/s
10GE WAN 9.95 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230, M520S IEEE 802.3ae
10GE LAN 10.31 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, E224, EMS20, M404DM, M502DM, M504DM, M210D, M520SM, TNV3T220E, TNG2M504S, TNG2M604SM, TNV6G216, G230, M520S
25GE 25.78 Gbit/s TNV7T220, T216, TNV6T230, TNV3E224, M520SM, TNV6G216, G230, M520S IEEE 802.3by
40GE 41.25 Gbit/s TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T410, T502, M404DM, M504DM, M520SM, M604SM, TNG2M504S, M520S IEEE 802.3ba
50GE 51.5625 Gbit/s T502, TNV3E402, M520SM, TNV3E404, M520S
100GE 103.125 Gbit/s G402, G404, TNG1T401, TNV3T401, TNV3T404, TNV3T402, TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T410, T502, E402, M402, M502DM, M504DM, M520SM, M604SM,TNG1M604S, TNG1M804SM, TNG2M504S, G3M402D, G3M504D, M520S
200GE 206.25 Gbit/s T502, TNG1M804SM
400GE 412.5 Gbit/s T601,TNG1M604S,TNG1M804SM
Flex Ethernet service (FlexE) FlexE Unaware (50G) 51.5625 Gbit/s T502 IA Flex Ethernet 2.1
FlexE Unaware (100G) 103.125 Gbit/s TNV8T402, TNV8T404, T502,TNG1M804SM, TNV5T401, TNV5T402,TNV7T402, TNV5T404, TNV1T410, TNG2M504DM
FlexE Unaware (200G) 206.25 Gbit/s TNG1M804SM
FlexE Aware (200G) 206.25 Gbit/s T502
FlexE Unaware (400G) 425 Gbit/s TNG3M504SP
SAN service FDDI 125 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230 , M520S ANSI X3.296 ANSI X3.230 ANSI X3.303
ESCON 200 Mbit/s
FC100/FICON 1.06 Gbit/s
FC200/FICON Express 2.12 Gbit/s
FC400/FICON4G 4.25 Gbit/s
FC800/FICON8G 8.5 Gbit/s
FC1200/FICON 10G 10.51 Gbit/s
FC1600 14.025 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, M520SM, TNV6G216, G230, M520S
FC1600-trunk-2 2 X 14.025Gbit/s M520SM, M520S
C1600-trunk-4 4 X 14.025Gbit/s
FC3200 28.05 Gbit/s T216, TNV7T220, TNV6T230, M520SM, TNV6G216, G230, M520S
OTN service OTU1 2.67 Gbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV3S216, TNV4S216, TNV6G216, G230, M520S ITU-T G.709 ITU-T G.959.1 GR-2918-CORE
OTU2 10.71 Gbit/s
OTU2e 11.10 Gbit/s
OTU4 111.81 Gbit/s G402, G404, M402, TNG1T401, TNV3T401, TNV3T402, TNV3T404, TNV5T401, TNV5T402, TNV5T404, TNV7T402, TNV8T402, TNV8T404, T410, T502, M502DM, M504DM, M520SM, M604SM, TNG2M504S,TNG1M804SM, G3M402D, G3M504D, M520S
Video service DVB-ASI 270 Mbit/s T212, T216, A212, T206, T210, T220, T230, G220, M210D, M520SM, TNV6G216, G230, M520S EN 50083-9
SD-SDI 270 Mbit/s SMPTE 259M
HD-SDIa 1.49 Gbit/s SMPTE 292M
HD-SDIRBR 1.49/1.001 Gbit/s
3G-SDIa 2.97 Gbit/s SMPTE 424M
3G-SDIRBR 2.97/1.001 Gbit/s
GE: Gigabit Ethernet
ESCON: enterprise system connection
FICON: Fibre Connect
FC: fiber channel
DVB-ASI: digital video broadcast-asynchronous serial interface
SD-SDI: standard definition-serial digital interface signal. For SMPTE-259M specifically, SD-SDI is also called SDI.
a: According to SMPTE 292M standards, both HD-SDI and 3G-SDI have two rates. The rates of HD-SDI are 1.485 Gbit/s and 1.485/1.001 Gbit/s, and those of 3G-SDI are 2.97 Gbit/s and 2.97/1.001 Gbit/s. The 1/1.001 factor is the parameter that complies with National Transportation Safety Committee (NTSC) standards. NTSC is the analog television system that is widely used in North America, some Latin America regions, South Korea, Japan, and some Pacific island nations and territories.

Reviews

  1. mark

    I bought one for trial, and everything was good.

  2. Sophia

    The device supports multiple transmission rates, including 10G, 40G, and 100G, and is easy to expand in the future, reducing upgrade costs.

Add a review

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart