Description
Item | NE40E-X16A DC |
Cabinet installation standard | Can be installed in a standard 19″ 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default. |
[2T bundle]Can be installed in a standard 19″ 1000 mm-deep cabinet,part number is 02115109(CR5B0N610E60) | |
Typical power consumption | 7720 W (fully configured with LPUF-240s) |
9040 W (fully configured with LPUF-480s) | |
12390 W (fully configured with LPUI-1Ts) | |
22450 W(fully configured with LPUI-2Ts) | |
Typical heat dissipation | 25046.9 BTU/hour (fully configured with LPUF-240s) |
29329.6 BTU/hour (fully configured with LPUF-480s) | |
40198.4 BTU/hour (fully configured with LPUI-1Ts) | |
72837.2 BTU/hour (fully configured with LPUI-2Ts) | |
DC input voltage | input voltage range: –40 V to –72 V |
input rated voltage: -48 V/–60 V | |
AC input voltage | input voltage range: 180 V to 264 V |
input rated voltage: 200 V to 240 V | |
HVDC input voltage | input voltage range: 192 to 288V,264 to 400V |
input rated voltage: 240 V/380 V | |
MTBF | 22.33 years |
MTTR | 0.5 hours |
Availability | 0.999997444 |
Slot quantity | 22 |
Redundant MPUs | 0.042361111 |
Redundant Switch fabrics | 3+1 |
Redundant fans | [1T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) |
[2T bundle] 2 partitions; 3 assemblies/partition; each partition in support for proper fan operation in case of a single fan failure for a short period at 40°C (104°F) | |
Redundant power supply | [1T bundle] DC: 9+1 |
[1T bundle] HVDC&AC: 7+1 | |
[2T bundle] DC: 12+1 | |
[2T bundle] HVDC&AC: 9+1 | |
Forwarding performance | 5600 Mpps (LPUF-240) |
Switching capacity | 50.32 Tbps (LPUI-1T) |
81.92 Tbps (LPUI-2T) | |
Operating temperature | Long-term: 0°C to 45°C (32°F to 113°F) |
Short-term: –5°C to +55°C (23°F to131°F) | |
Remark: Restriction on the temperature variation rate: 30°C/hour (86°F/h) | |
Storage temperature | –40°C to +70°C (–40°F to +158°F) |
Relative operating humidity | Long term: 5% to 85% RH, non-condensing |
Short term: 5% to 95% RH, non-condensing | |
Relative storage humidity | 5% to 95% RH, non-condensing |
Long-term operating altitude | <= 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the NEU100 must decrease by 1°C [33.8°F] for every 220 m [721.78 ft.].) |
Storage altitude | Less than 5000 m (16404 ft.) |
Dimensions (H x W x D) | (40 U) 1778 mm x 442 mm x 650 mm (70.00 in. x 17.40 in. x 25.59 in.) (Chassis main body) |
(40 U) 1778 mm x 442 mm x 750 mm (70.00 in. x 17.40 in. x 29.53 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) | |
[2T bundle](40 U) 1778 mm x 442 mm x 946 mm (70.00 in. x 17.40 in. x 37.24 in.) (Dimensions of the chassis body together with cable trays and front and back attachments) | |
Weight (empty) | DC: 120.5 kg (265.7 lb) (without filler panels) |
HVDC&AC: 111.7 kg (246.3 lb) (without filler panels) | |
Weight (full configuration) | [1T bundle] DC:399.4 kg (880.68 lb) |
[1T bundle] HVDC&AC:395.1 kg (871.2 lb) | |
[2T bundle] DC:461.3kg(1017.0 lb) | |
[2T bundle] HVDC&AC:453.3kg(999.34 lb) |