NE40E-M2H Integrated Chassis Components

Description

Item NE40E-M2H
Typical power consumption (with configuration) [W] DC: 487 W

AC: 525 W

Typical heat dissipation (with configuration) [BTU/hour] DC: 1580 BTU/hour

AC: 1703.3 BTU/hour

MTBF [year] 23 year
MTTR [hour] 2 hour
Availability 0.999990074
CPU 16-core, 2.0 GHz
SDRAM 16 G
Flash memory 128 MB
Storage 4 GB
Power supply mode
  • DC
  • AC
  • HVDC
Rated input voltage [V] DC: -48 V/-60 V

AC: 200 V to 240 V/100 V to 127 V dual live wires

HVDC: 240 V

Input voltage range [V] DC: -48 V/-72 V

AC: 180 V to 264 V

HYDC: 188 Vdc to 290 Vdc

Maximum input current [A] DC: 18 A

AC: 5.4 A

HVDC: 4.8 A

Maximum input cable size [mm²] DC: 6mm^2. 4mm^2 (1-15 meters) recommended

AC: 1.5mm^2

Front-end circuit breaker/fuse [A] DC: ≥20 A

AC: ≥6 A

HVDC: ≥6.3 A

Heat dissipation mode Air cooling
Airflow direction From left to right
Noise at normal temperature (acoustic power) [dB(A)] < 72 dB (meeting the ETSI 72 dBA standard)
Number of slots 6
Number of service board slots 2
Switching capacity 960 Gbit/s
Maximum number of physical ports on the entire device 84
Maximum number of 100GE ports 2
Maximum number of 50GE ports 4
Maximum number of 40GE ports 2
Maximum number of 10GE ports 48
Maximum number of GE ports 68
Redundant MPUs Fixed-configuration, not pluggable
Redundant network processing units Fixed-configuration, not pluggable
Redundant power supply 1+1
Redundant fans If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.
Long-term operating temperature [°C(°F)] 0°C(33.8°F) to 45°C(113°F)
Short-term operating temperature [°C(°F)] AC: –5°C to +55°C (23°F to 131°F)
Restriction on the operating temperature variation rate [°C(°F)] ≤ 0.5°C/min (32.9°F/min), non-condensing
Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158 °F)
Long-term operating relative humidity [RH] 5% RH to 90% RH, non-condensing
Short-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Storage relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].)
Storage altitude [m(ft.)] < 5000 m (16404.2 ft.)
Cabinet installation standards ETSI 21-inch; IEC 19-inch
Dimensions without packaging (H x W x D) [mm(in.)] 88.1 mm x 442 mm x 220 mm (3.47 in. x 17.40 in. x 8.66 in.)
Chassis height [U] 2U
Weight without packaging [kg(lb)] 9.1 kg (20.06 lb)
Weight without packaging (full configuration) [kg(lb)] DC: 10.7 kg (23.59 lb)

AC: 11.9 kg (26.24 lb)

Additional information

Weight 30.0000 kg
Dimensions 65.0000 × 45.0000 × 27.0000 cm