NE40E-F1A-14H24Q Integrated Chassis Components

Description

Item NE40E-F1A-14H24Q
Typical power consumption (with configuration) [W] 470 W
Typical heat dissipation (with configuration) [BTU/hour] 1524.9 BTU/hour
MTBF [year] 26.2 year
MTTR [hour] 2 hour
Availability 0.9999912859
CPU 16-core, 2.0 GHz
SDRAM 16 GB
Flash memory 128 MB
Storage 4 GB
Power supply mode
  • DC
  • AC/HVDC
Rated input voltage [V] DC: -48 V/-60 V

AC: 100 V to 240 V

HVDC: 240 V DC

Input voltage range [V] DC: –40 V to –72 V

AC: 90 V to 290 V

HVDC: 188 V DC to 290 V DC

Maximum input current [A] DC: 38 A

AC: 10 A

HVDC: 8 A

Maximum input cable size [mm²] DC: 6 mm^2(<25 meters). 4 mm^2 (1-15 meters) recommended.

AC: 2.5 mm^2

HVDC: 2.5 mm^2

Front-end circuit breaker/fuse [A] DC: ≥40 A

AC: ≥10 A

HVDC: ≥8 A

Heat dissipation mode Air cooling
Airflow direction Front to back: port-side intake
Noise at normal temperature (acoustic power) [dB(A)] < 72 dB (meeting the ETSI 72 dBA standard)
Noise at high temperature (acoustic power) [dB(A)] < 72 dB (meeting the ETSI 72 dBA standard)
Number of slots 8
Number of service board slots 1
Switching capacity 4 Tbit/s
Maximum number of physical ports on the entire device 44
Maximum number of 100GE ports 20
Maximum number of 40GE ports 20
Maximum number of 25GE ports 24
Maximum number of 10GE ports 24
Maximum number of GE ports 24
Redundant power supply 1+1
Redundant fans If a single fan fails, the system can still work for a short period of time at an ambient temperature of 40°C.
Long-term operating temperature [°C(°F)] –5°C to +45°C (23°F to 113°F)
Restriction on the operating temperature variation rate [°C(°F)] ≤ 0.5°C/min (32.9°F/min), non-condensing
Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158 °F)
Long-term operating relative humidity [RH] 5% RH to 85% RH, non-condensing
Short-term operating relative humidity [RH] 5% RH to 95% RH, non-condensing
Storage relative humidity [RH] 5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)] ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device decreases by 1°C [33.8°F] each time the altitude increases by 220 m [721.78 ft.].)
Storage altitude [m(ft.)] < 5000 m(< 16404.2 ft.)
Breakout supported Yes. Only 100GE interfaces support interface splitting.

To enable interface splitting, run the port split command.

FlexE supported No
Cabinet installation standards ETSI 21-inch; IEC 19-inch
Dimensions without packaging (H x W x D) [mm(in.)] 43.6 mm x 442 mm x 600 mm (1.72 in. x 17.40 in. x 23.62 in.)
Chassis height [U] 1U
Weight without packaging [kg(lb)] 12 kg (26.46 lb)

Additional information

Weight 30.0000 kg
Dimensions 65.0000 × 45.0000 × 27.0000 cm