UPS2000-G

0 Reviews Write a review
SKU2027149
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Original price was: $0.00.Current price is: $0.00.

Huawei  UPS2000-G with high-quality AC power and can be towered- or rack-mounted

Description

UPS2000-G Overview

The UPS2000-G is a power supply solution for micro data centers and critical power supply scenarios. It is an online double conversion system that safely delivers uninterrupted, high-quality AC power and can be towered- or rack-mounted.

Series UPS2000-G(15 kVA) UPS2000-G(20 kVA)
Capacity 15 kVA 20kVA
Product Type Rack-mounted Rack-mounted
Input Voltage 220/230/240 V (1Ph)
380/400/415 V (3Ph)
220/230/240 V (1Ph)
380/400/415 V (3Ph)
Operating Temperature 0~40°C 0~40°C
Output Power Factor 0.9 0.9
Efficiency (Double Conversion Mode) 95.0% 95.0%
Dimensions (W×D×H, mm) 430×757×130 430×757×130

 

UPS2000-G Datasheet

Item

15 kVA

20 kVA

Input power cable

  • Single-phase (L/N) input + PE cable

  • Three-phase (L1/L2/L3/N) input + PE cable

  • Single-phase (L/N) input + PE cable

  • Three-phase (L1/L2/L3/N) input + PE cable

Rated input voltage

  • 208 V AC, 220 V AC, 230 V AC, or 240 V AC (single-phase input)
  • 380 V AC, 400 V AC, or 415 V AC (three-phase input)
  • 208 V AC, 220 V AC, 230 V AC, or 240 V AC (single-phase input)
  • 380 V AC, 400 V AC, or 415 V AC (three-phase input)

Input voltage

  • 80–280 V AC, single-phase (When the voltage is 80–176 V AC, the load power is linearly derated to 40%–100%.)

  • 138–485 V AC, three-phase (When the voltage is 138–305 V AC, the load power is linearly derated to 40%–100%.)

  • 80–280 V AC, single-phase (When the voltage is 80–176 V AC, the load power is linearly derated to 40%–100%.)

  • 138–485 V AC, three-phase (When the voltage is 138–305 V AC, the load power is linearly derated to 40%–100%.)

Input power factor (100% resistive load)

> 0.99

No-load loss

< 200 W

Double-power input

Enabled

Startup voltage

120–280 V AC

Generator input capacity

Minimum 1.5 times the UPS rated capacity

Overvoltage category

OVC Ⅱ

Bypass voltage

  • Upper threshold: 10%, 15%, 20%, 25%, or 30% at 208 V AC
  • Upper threshold: 10%, 15%, 20%, or 25% at 220 V AC

  • Upper threshold: 10%, 15%, or 20% at 230 V AC

  • Upper threshold: 10% or 15% at 240 V AC

  • Lower threshold: 10%, 20%, 30%, 40%, 50%, or 60%

Bypass frequency tolerance

Maximum ±6 Hz (configurable on the LCD)

Bypass overload capability

  • When the UPS works continuously at a load rate of less than 125%, the input switch may trip in advance.

  • When the load rate is within 125%–150%, the UPS disconnects the output after 1 minute, and the input switch may trip in advance.

  • When the load rate is greater than or equal to 150%, the UPS disconnects the output after 100 ms, and the input switch may trip in advance.

Input mode

  • One power source

  • Two power sources

Dimensions (H x W x D)

430 mm x 130 mm x 757 mm

Weight

32 kg

IP rating

IP20

Additional information

Brand

Huawei

UPS2000-G Datasheet

Item

15 kVA

20 kVA

Input power cable

  • Single-phase (L/N) input + PE cable

  • Three-phase (L1/L2/L3/N) input + PE cable

  • Single-phase (L/N) input + PE cable

  • Three-phase (L1/L2/L3/N) input + PE cable

Rated input voltage

  • 208 V AC, 220 V AC, 230 V AC, or 240 V AC (single-phase input)
  • 380 V AC, 400 V AC, or 415 V AC (three-phase input)
  • 208 V AC, 220 V AC, 230 V AC, or 240 V AC (single-phase input)
  • 380 V AC, 400 V AC, or 415 V AC (three-phase input)

Input voltage

  • 80–280 V AC, single-phase (When the voltage is 80–176 V AC, the load power is linearly derated to 40%–100%.)

  • 138–485 V AC, three-phase (When the voltage is 138–305 V AC, the load power is linearly derated to 40%–100%.)

  • 80–280 V AC, single-phase (When the voltage is 80–176 V AC, the load power is linearly derated to 40%–100%.)

  • 138–485 V AC, three-phase (When the voltage is 138–305 V AC, the load power is linearly derated to 40%–100%.)

Input power factor (100% resistive load)

> 0.99

No-load loss

< 200 W

Double-power input

Enabled

Startup voltage

120–280 V AC

Generator input capacity

Minimum 1.5 times the UPS rated capacity

Overvoltage category

OVC Ⅱ

Bypass voltage

  • Upper threshold: 10%, 15%, 20%, 25%, or 30% at 208 V AC
  • Upper threshold: 10%, 15%, 20%, or 25% at 220 V AC

  • Upper threshold: 10%, 15%, or 20% at 230 V AC

  • Upper threshold: 10% or 15% at 240 V AC

  • Lower threshold: 10%, 20%, 30%, 40%, 50%, or 60%

Bypass frequency tolerance

Maximum ±6 Hz (configurable on the LCD)

Bypass overload capability

  • When the UPS works continuously at a load rate of less than 125%, the input switch may trip in advance.

  • When the load rate is within 125%–150%, the UPS disconnects the output after 1 minute, and the input switch may trip in advance.

  • When the load rate is greater than or equal to 150%, the UPS disconnects the output after 100 ms, and the input switch may trip in advance.

Input mode

  • One power source

  • Two power sources

Dimensions (H x W x D)

430 mm x 130 mm x 757 mm

Weight

32 kg

IP rating

IP20