UPS2000-A-3KTTL

0 Reviews Write a review
SKU2027138
AvailabilityIn Stock
WarrantyUp to 36 months i
×
Warranty Policy
We provide a comprehensive warranty policy.
Refer to the table for more details.

Original price was: $0.00.Current price is: $0.00.

Huawei UPS2000-A Series 2KTTL 3000 VA/2400 W with external battery

Description

UPS2000-A-3KTTL Overview

Model

Represented By

Remarks

UPS2000-A-1KTTS

1K-standard backup time model-tower mounted-IEC

  1. The tower-mounted model provides three configurations: 1 kVA, 2 kVA, and 3 kVA.
  2. Each configuration has standard backup time or long backup time.

UPS2000-A-1KTTL

1K-long backup time model-tower mounted-IEC

UPS2000-A-2KTTS

2K-standard backup time model-tower mounted-IEC

UPS2000-A-2KTTL

2K-long backup time model-tower mounted-IEC

UPS2000-A-3KTTS

3K-standard backup time model-tower mounted-IEC

UPS2000-A-3KTTL

3K-long backup time model-tower mounted-IEC

UPS2000-A-3KTTL Structure

UPS2000-A

(1) Mains input socket (1 kVA/2 kVA: C14; 3 kVA: C20)

(2) Input circuit breaker

(3) USB porta (security protection mechanism supported)

(4) RS232 port

(5) Optional card slot

(6) External battery connector (only for long backup time models)

(7) Output socket (10 A)

(8) Output terminal (connecting to 2.5 mm2 cables)

UPS2000-A-3KTTL Datasheet
Item UPS2000-A-3KTTL
Input power cable Single-phase (L/N) input +PE cable
Rated input voltage 200 V AC/208 V AC/220 V AC/230 V AC/240 V AC
Lowest conversion voltage
  • When the ambient temperature is 0–35°C:

    160 V AC/140 V AC/120 V AC/110 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

  • When the ambient temperature is 35–40°C:

    175 V AC/155 V AC/135 V AC/125 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

Lowest recovery voltage
  • When the ambient temperature is 0–35°C:

    175 V AC/155 V AC/135 V AC/125 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

  • When the ambient temperature is 35–40°C:

    190 V AC/170 V AC/150 V AC/140 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

Highest conversion voltage
  • 300 V AC±5% (load rate: less than 80%)
  • 280 V AC±5% (load rate: 80%–100%; transfer to battery mode after 15 minutes)
Highest recovery voltage
  • 290 V AC±5% (load rate: less than 80%)
  • 270 V AC±5% (load rate: greater than 80%)
Input power factor (100% resistive load) > 0.99
Startup voltage 120–280 V AC
Generator input capacity Minimum 1.5 times the UPS rated capacity
Operating temperature 0°C–40°C
Humidity 0%–95% RH (non-condensing)
Altitude < 1000 m
Storage and transportation temperature –40°C to +70°C (battery pack: –20°C to +40°C)
Noise < 50 dBA @ 1 m
IP rating IP20
Net Dimensions (H x W x D) 220 mm x 145 mm x 397 mm
Net Weight 8.0 kg

Additional information

Brand

Huawei

UPS2000-A-3KTTL Datasheet
Item UPS2000-A-3KTTL
Input power cable Single-phase (L/N) input +PE cable
Rated input voltage 200 V AC/208 V AC/220 V AC/230 V AC/240 V AC
Lowest conversion voltage
  • When the ambient temperature is 0–35°C:

    160 V AC/140 V AC/120 V AC/110 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

  • When the ambient temperature is 35–40°C:

    175 V AC/155 V AC/135 V AC/125 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

Lowest recovery voltage
  • When the ambient temperature is 0–35°C:

    175 V AC/155 V AC/135 V AC/125 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

  • When the ambient temperature is 35–40°C:

    190 V AC/170 V AC/150 V AC/140 V AC±5% (depending on the load rate: 100%–80%/80%–70%/70%–60%/60%–0)

Highest conversion voltage
  • 300 V AC±5% (load rate: less than 80%)
  • 280 V AC±5% (load rate: 80%–100%; transfer to battery mode after 15 minutes)
Highest recovery voltage
  • 290 V AC±5% (load rate: less than 80%)
  • 270 V AC±5% (load rate: greater than 80%)
Input power factor (100% resistive load) > 0.99
Startup voltage 120–280 V AC
Generator input capacity Minimum 1.5 times the UPS rated capacity
Operating temperature 0°C–40°C
Humidity 0%–95% RH (non-condensing)
Altitude < 1000 m
Storage and transportation temperature –40°C to +70°C (battery pack: –20°C to +40°C)
Noise < 50 dBA @ 1 m
IP rating IP20
Net Dimensions (H x W x D) 220 mm x 145 mm x 397 mm
Net Weight 8.0 kg

Reviews

There are no reviews yet.

Be the first to review “UPS2000-A-3KTTL”

Your email address will not be published. Required fields are marked *

Back to Top

Search For Products

Product has been added to your cart